COMPANY HEADER
Medical Claw Open Systems

The claw pump design is extremely efficient and has very low maintenance cost; because there is no actual contact between the rotors and the cylinder wall, parts that need replacing or required maintenance is minimized.
Request Information Search by Specification
Unit of Measure
Items
CVTD-HMI-5-570x570.jpg

2 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0203

CVTD-HMI-5-570x570.jpg

2 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0203V

CVTD-HMI-5-570x570.jpg

3 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0303

CVTD-HMI-5-570x570.jpg

3 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0303V

CVTD-HMI-5-570x570.jpg

4 HP Duplex Tankmount Medical Claw Open Vaccum System CVTD0504A
Description N/A Medical Claw Open Systems

The claw pump design is extremely efficient and has very low maintenance cost; because there is no actual contact between the rotors and the cylinder wall, parts that need replacing or required maintenance is minimized.
Length (A) N/A 71 in N/A 71 in N/A 71 in N/A 71 in N/A 77 in
Width (B) N/A 42 in N/A 42 in N/A 42 in N/A 42 in N/A 43 in
Height (C) N/A 68 in N/A 68 in N/A 68 in N/A 68 in N/A 72 in
Inlet Connection Size N/A 1.5 in N/A 1.5 in N/A 1.5 in N/A 1.5 in N/A 2 in
Outlet Connection Size N/A 1 in
Pump Power N/A 2 hp N/A 2 hp N/A 3 hp N/A 3 hp N/A 4 hp
Air Flow at 19 inHg1 N/A 16 scfm N/A 16 scfm N/A 21 scfm N/A 21 scfm N/A 29 scfm
Tank Capacity N/A 80 gal N/A 80 gal N/A 80 gal N/A 80 gal N/A 120 gal
Tank Orientation N/A Horizontal N/A Vertical N/A Horizontal N/A Vertical N/A Horizontal
Compressor Capacity N/A 4,335 Btu/hr N/A 4,335 Btu/hr N/A 6,503 Btu/hr N/A 6,503 Btu/hr N/A 8,670 Btu/hr
Sound Level N/A 70 dBA N/A 70 dBA N/A 70 dBA N/A 70 dBA N/A 79 dBA
System Full Load Current (F.L.A) at 208 Volts N/A 14.4 A N/A 14.4 A N/A 20.8 A N/A 20.8 A N/A 22 A
System Full Load Current (F.L.A) at 230 Volts N/A 13.2 A N/A 13.2 A N/A 18.8 A N/A 18.8 A N/A 20.4 A
System Full Load Current (F.L.A) at 460 Volts N/A 7.6 A N/A 7.6 A N/A 10.4 A N/A 10.4 A N/A 11.2 A
System Weight N/A 1000 lb N/A 1000 lb N/A 1,200 lb N/A 1,200 lb N/A 1,400 lb
Brands N/A Powerex®
Electrical Panel Opening N/A 42 in
Minimum Clearance for Ease of Maintenance N/A 24 in
Motor Voltage N/A 208 V230 V460 V
Phase N/A 3
Power Supply Frequency N/A 60 Hz
Vacuum System N/A The Powerex medical vacuum system is designed to create a suction system to remove unwanted fluids or gases from hospital/ laboratory working areas. The medical vacuum system package is compliant with the NFPA 99 requirements for Risk Category 1 systems. Each system is completely tested before shipment and includes:

• Multiple vacuum pumps and associated equipment.
• AMSE air receiver.
• Medical control panel. Each pump is factory piped to a common intake manifold. Vibration isolation pads are included with the system.
Rotary Vane Vacuum Pump N/A Each pump shall be a rotary claw type vacuum pump, and shall be direct-driven through a shaft coupling by a C-face, TEFC electric motor.

• Each vacuum pump shall be dry-running, featuring two claw-type, non-contacting rotors and shall not require any sealing fluid in the pumping chamber, assuring virtually maintenance-free operation.
• Each vacuum pump shall include an internal relief valve, and a built-in, anti-suck-back valve mounted at the pump inlet.
• Each pump within the system shall include a check valve, inlet and discharge flex connectors, a 5 micron inlet filter and a pump isolation valve.
Motor N/A The motor is continuous duty, C-face, TEFC, suitable for 208-230, or 460V, 3 phase, 60 hertz electrical operation.
Receiver N/A The system shall include an ASME rated air receiver. The tank shall be equipped with a vacuum gauge, a sight gauge, by-pass valves, and a manual drain.
Control Panel N/A The control system provides automatic lead/lag sequencing and automatic alternation of all pumps in order to equalize the amount of usage among the available vacuum pumps. The Premium NFPA Control panel shall include a gateway server card and all features listed below:
  • PLC controller and a color touch screen panel which displays the operating status of the unit.
  • Building automation communication gateway with BacNet® protocol and Web server features. Web servers features include email notifications in case the system is in alarm or has achieved one its maintenance intervals and requires service.
  • Ethernet port for connection to BacNet® server or direct connection to facility Ethernet for viewing of system operations and status via device IP-address.
  • UL508A listed control panel in a NEMA 12 enclosure. The panel door will include: the HMI touch screen, an audible and visual alarms with an acknowledge button, and an HOA switch for each pump.
  • Magnetic starters.
  • Vacuum transducer for process control.
  • Single point power connection.
  • Redundant 120Vac control transformers with fused primary and secondary protection.
  • System overload trip, high temperature conditions or maintenance intervals for the pump will result in visual and audible alarms.
Available Options N/A • Oxygen assured pumps - prepared for use in WAGD systems.
• Internal tank lining for corrosion resistance.
• Variable Frequency Drive (VFD) Control Panel – with Premium NFPA controls.
Note N/A 3 Year Limited Warranty
Additional Information N/A Benefit & Features
  • Energy efficient technology
  • Oil-free compression chamber
  • Low maintenance
  • No water and sewage costs
  • Suitable for dedicated waste anesthesia systems
  • Expandable configurations for skid mounted systems up to quadplex
  • Fully compliant with NFPA 99
  • Manufactured in ISO 9001:2015 certified facilities
  • 1 Air Flow shown at total system capacity.