FA 500 is the ideal dew point measuring instrument with integrated display and alarm relay for refrigeration, membrane and adsorption dryers.
Unit of Measure
Items
FA 500 Dew Point Sensors

FA 500, -112 to 68 Degree Fahrenheit (ºF) Measuring Range (Atmospheric Pressure) Dew Point Sensor
Web Price Quote

FA 500 Dew Point Sensors

FA 500, -76 to 86 Degree Fahrenheit (ºF) Measuring Range (Atmospheric Pressure) Dew Point Sensor
Web Price Quote

FA 500 Dew Point Sensors

FA 500, -4 to 122 Degree Fahrenheit (ºF) Measuring Range (Atmospheric Pressure) Dew Point Sensor
Web Price Quote

Image

16 Feet (ft) Length Cable for Alarm/Pulse Output
Web Price Quote

Image

32.81 Feet (ft) Length Cable for Alarm/Pulse Output
Web Price Quote
Description N/A FA 500 is the ideal dew point measuring instrument with integrated display and alarm relay for refrigeration, membrane and adsorption dryers. N/A FA 500 is the ideal dew point measuring instrument with integrated display and alarm relay for refrigeration, membrane and adsorption dryers. N/A FA 500 is the ideal dew point measuring instrument with integrated display and alarm relay for refrigeration, membrane and adsorption dryers. N/A Cable for alarm/pulse output, with M12 plug, length 16 ft N/A Cable for alarm/pulse output, with M12 plug, length 32.81 ft
Approve Payments N/A Finance with Approve Payments

Length N/A N/A N/A N/A 16 ft N/A 32.81 ft
Voltage N/A
Frequency N/A
Alternating Current (AC) Voltage N/A
Direct Current (DC) N/A
Measuring Range (Atmospheric Pressure) N/A -112 to 68 ºF N/A -76 to 86 ºF N/A -4 to 122 ºF N/A N/A
Relative Humidity N/A N/A N/A 100 % N/A N/A
Accuracy (±) at 122 to -4 Degree Fahrenheit (ºF) Temperature N/A 1.8 ºF N/A 1.8 ºF N/A 1.8 ºF N/A N/A
Accuracy (±) at -4 to -58 Degree Fahrenheit (ºF) Temperature (Atmospheric Pressure) N/A 3.6 ºF N/A 3.6 ºF N/A 3.6 ºF N/A N/A
Accuracy (±) at -58 to -112 Degree Fahrenheit (ºF) Temperature (Atmospheric Pressure) N/A 5.4 ºF N/A 5.4 ºF N/A 5.4 ºF N/A N/A
Pressure Range N/A -1 to 50 bar N/A -1 to 50 bar N/A -1 to 50 bar N/A N/A
Pressure Range (Special Version) N/A 7251 psi N/A 7251 psi N/A 7251 psi N/A N/A
Direct Current (DC) Voltage N/A 10 to 36 V24 V N/A 10 to 36 V24 V N/A 10 to 36 V24 V N/A N/A
Protection Class N/A IP 65 N/A IP 65 N/A IP 65 N/A N/A
Electromagnetic Compatibility (EMC) N/A In According with DIN EN 61326-1 N/A In According with DIN EN 61326-1 N/A In According with DIN EN 61326-1 N/A N/A
Operating Temperature N/A -4 to 122 ºF N/A -4 to 122 ºF N/A -4 to 122 ºF N/A N/A
Connection N/A 2 x M12, 5-pin for analog output, Modbus-RTU and alarm output, M-Bus (optional) Ethernet (PoE) (optional) N/A 2 x M12, 5-pin for analog output, Modbus-RTU and alarm output, M-Bus (optional) Ethernet (PoE) (optional) N/A 2 x M12, 5-pin for analog output, Modbus-RTU and alarm output, M-Bus (optional) Ethernet (PoE) (optional) N/A N/A
Personal Computer (PC) Connection N/A Modbus-RTU interface (RS 485) N/A Modbus-RTU interface (RS 485) N/A Modbus-RTU interface (RS 485) N/A N/A
Analog Output N/A 4 to 20 mA = -112 to 68 °Ftd 4 to 20 mA = -4 to 122 °Ftd 4 to 20 mA = -76 to 86 °Ftd N/A 4 to 20 mA = -112 to 68 °Ftd 4 to 20 mA = -4 to 122 °Ftd 4 to 20 mA = -76 to 86 °Ftd N/A 4 to 20 mA = -112 to 68 °Ftd 4 to 20 mA = -4 to 122 °Ftd 4 to 20 mA = -76 to 86 °Ftd N/A N/A
Burden for Analog Output N/A < 500 Ω N/A < 500 Ω N/A < 500 Ω N/A N/A
Alarm Relay N/A NC, max. 60 VDC, 0.5 A N/A NC, max. 60 VDC, 0.5 A N/A NC, max. 60 VDC, 0.5 A N/A N/A
Screw-In Thread N/A G 1/2 in. N/A G 1/2 in. N/A G 1/2 in. N/A N/A
Width N/A 3.01 in N/A 3.01 in N/A 3.01 in N/A N/A
Depth N/A 3.35 in N/A 3.35 in N/A 3.35 in N/A N/A
Height N/A 2.95 in N/A 2.95 in N/A 2.95 in N/A N/A
Material N/A
Type N/A
Special Features N/A
  • Integrated display
  • Threshold value adjustable via keypad, alarm relay (max. 60 VDC, 0.5 A)
  • Pressure-tight up to 7251 psi (special version)
  • Extremely stable in the long term
  • Quick adaption time
  • 4...20 mA analog output for dew point
  • Different refrigeration and adsorption dryer versions
  • NEW: Modbus-RTU interface
  • NEW: Higher resolution of sensor signal due to the improved evaluation electronics
  • NEW: Sensor diagnosis on site with a portable device or CS Service Software
N/A
  • Integrated display
  • Threshold value adjustable via keypad, alarm relay (max. 60 VDC, 0.5 A)
  • Pressure-tight up to 7251 psi (special version)
  • Extremely stable in the long term
  • Quick adaption time
  • 4...20 mA analog output for dew point
  • Different refrigeration and adsorption dryer versions
  • NEW: Modbus-RTU interface
  • NEW: Higher resolution of sensor signal due to the improved evaluation electronics
  • NEW: Sensor diagnosis on site with a portable device or CS Service Software
N/A
  • Integrated display
  • Threshold value adjustable via keypad, alarm relay (max. 60 VDC, 0.5 A)
  • Pressure-tight up to 7251 psi (special version)
  • Extremely stable in the long term
  • Quick adaption time
  • 4...20 mA analog output for dew point
  • Different refrigeration and adsorption dryer versions
  • NEW: Modbus-RTU interface
  • NEW: Higher resolution of sensor signal due to the improved evaluation electronics
  • NEW: Sensor diagnosis on site with a portable device or CS Service Software
N/A N/A
Readable via Modbus N/A
  • Pressure dew point [ºFtd]
  • Temperature [ºF]
  • rel. humidity [% RH]
  • abs. humidity [g/m³]
  • Degree of humidity [g/kg]
  • Moisture content V/V [ppmV/V]
  • Partial vapor pressure [hPa]
  • Atmospheric dew point [ºFtd.atm]
N/A
  • Pressure dew point [ºFtd]
  • Temperature [ºF]
  • rel. humidity [% RH]
  • abs. humidity [g/m³]
  • Degree of humidity [g/kg]
  • Moisture content V/V [ppmV/V]
  • Partial vapor pressure [hPa]
  • Atmospheric dew point [ºFtd.atm]
N/A
  • Pressure dew point [ºFtd]
  • Temperature [ºF]
  • rel. humidity [% RH]
  • abs. humidity [g/m³]
  • Degree of humidity [g/kg]
  • Moisture content V/V [ppmV/V]
  • Partial vapor pressure [hPa]
  • Atmospheric dew point [ºFtd.atm]
N/A N/A
Easy Operation Via Keys on Display N/A The integrated display shows the dew point in big figures as well as further humidity parameters on two more display pages. The arrow key can be used to scroll between the display pages.

The alarm threshold value for the integrated relay can be freely entered via the keys. In addition to the alarm threshold, the hysteresis can also be freely entered.

The 4 to 20 mA analog output can be scaled freely or also allocated to one further parameter, e. g. g/m³.

After entering the system pressure of the compressed air system and the reference pressure (atmospheric pressure), the sensor can also calculate back to the atmospheric dew point from the measured pressure dew point if desired.
N/A The integrated display shows the dew point in big figures as well as further humidity parameters on two more display pages. The arrow key can be used to scroll between the display pages.

The alarm threshold value for the integrated relay can be freely entered via the keys. In addition to the alarm threshold, the hysteresis can also be freely entered.

The 4 to 20 mA analog output can be scaled freely or also allocated to one further parameter, e. g. g/m³.

After entering the system pressure of the compressed air system and the reference pressure (atmospheric pressure), the sensor can also calculate back to the atmospheric dew point from the measured pressure dew point if desired.
N/A The integrated display shows the dew point in big figures as well as further humidity parameters on two more display pages. The arrow key can be used to scroll between the display pages.

The alarm threshold value for the integrated relay can be freely entered via the keys. In addition to the alarm threshold, the hysteresis can also be freely entered.

The 4 to 20 mA analog output can be scaled freely or also allocated to one further parameter, e. g. g/m³.

After entering the system pressure of the compressed air system and the reference pressure (atmospheric pressure), the sensor can also calculate back to the atmospheric dew point from the measured pressure dew point if desired.
N/A N/A
Options N/A Z695 5004, M-Bus Board for VA 500/520 and FA 500 Z695 5006, Ethernet-Interface PoE for VA 500/520 and FA 500 Z695 5007, Ethernet-Interface Power over Ethernet (PoE) for VA 500/520 and FA 500 Z699 0511, 5/8 Inch (in) Unified National Fine (UNF) Connection Thread Z699 0514, Special Scaling Z699 0515, 5076 Pounds Per Square Inch (PSI) Maximum Pressure Z699 0516, 72551 Pounds Per Square Inch (PSI) Maximum Pressure Z699 0517, Surface Condition N/A Z695 5004, M-Bus Board for VA 500/520 and FA 500 Z695 5006, Ethernet-Interface PoE for VA 500/520 and FA 500 Z695 5007, Ethernet-Interface Power over Ethernet (PoE) for VA 500/520 and FA 500 Z699 0511, 5/8 Inch (in) Unified National Fine (UNF) Connection Thread Z699 0514, Special Scaling Z699 0515, 5076 Pounds Per Square Inch (PSI) Maximum Pressure Z699 0516, 72551 Pounds Per Square Inch (PSI) Maximum Pressure Z699 0517, Surface Condition N/A Z695 5004, M-Bus Board for VA 500/520 and FA 500 Z695 5006, Ethernet-Interface PoE for VA 500/520 and FA 500 Z695 5007, Ethernet-Interface Power over Ethernet (PoE) for VA 500/520 and FA 500 Z699 0511, 5/8 Inch (in) Unified National Fine (UNF) Connection Thread Z699 0514, Special Scaling Z699 0515, 5076 Pounds Per Square Inch (PSI) Maximum Pressure Z699 0516, 72551 Pounds Per Square Inch (PSI) Maximum Pressure Z699 0517, Surface Condition N/A N/A