Flex Flexible Industrial Process Chillers
IPC
- Refrigerant R410A
- Scroll compressors
- High-efficiency shell & tube evaporators
- Free-cooling version available
Unit of Measure
| Items |
/Asset/a8654.jpg IPC-0067-R454 6.7 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
/Asset/a8654.jpg IPC-0089-R454 8.9 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
/Asset/a8654.jpg IPC-0102-R454 10.2 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
/Asset/a8654.jpg IPC-0133-R454 13.3 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
/Asset/a8654.jpg IPC-0179-R454 17.9 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
|||||
| Description |
N/A
|
|||||||||
| Brands | N/A IPC Industrial Process Cooling | |||||||||
| Cooling Capacity | N/A 6.7 ton80400 Btu/hr | N/A 8.9 ton106800 Btu/hr | N/A 10.2 ton122400 Btu/hr | N/A 13.3 ton159600 Btu/hr | N/A 17.9 ton214800 Btu/hr | |||||
| Fluid Connections | N/A 1-1/2 inMale Pipe Thread (MPT) | |||||||||
| Nominal Flow | N/A 16 gpm | N/A 20 gpm | N/A 25 gpm | N/A 30 gpm | N/A 35 gpm | |||||
| Nominal Head Pressure | N/A 60 psi | N/A 70 psi | N/A 70 psi | N/A 70 psi | N/A 70 psi | |||||
| Reservoir Capacity | N/A 32 gal | N/A 58 gal | N/A 58 gal | N/A 58 gal | N/A 58 gal | |||||
| Power Supply Voltage | N/A 460 V | |||||||||
| Power Supply Phase | N/A 3 | |||||||||
| Power Supply Frequency | N/A 60 Hz | |||||||||
| Full Load Current | N/A 20.2 A | N/A 25.0 A | N/A 26.9 A | N/A 31.8 A | N/A 46 A | |||||
| Length | N/A 56 in | N/A 74 in | N/A 74 in | N/A 74 in | N/A 97 in | |||||
| Width | N/A 30 in | N/A 31 in | N/A 31 in | N/A 31 in | N/A 42 in | |||||
| Height | N/A 63 in | N/A 65 in | N/A 65 in | N/A 65 in | N/A 84 in | |||||
| Installed Weight | N/A 995 lb | N/A 1,454 lb | N/A 1,459 lb | N/A 1,498 lb | N/A | |||||
| Dry Weight | N/A 904 lb | N/A 1102 lb | N/A 1102 lb | N/A 1102 lb | N/A 1918 lb | |||||
| Fluid Out/In Temperature | N/A 45 ºF55 ºF | |||||||||
| Ambient Temperature | N/A 95 ºF | |||||||||
| Minimum Fluid Outlet Temperature | N/A 41 ºF | |||||||||
| Maximum Fluid Outlet Temperature | N/A 86 ºF | |||||||||
| Maximum Ambient Temperature | N/A 113 ºF | |||||||||
| Correction Factor at 30 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 0.68 | |||||||||
| Correction Factor at 35 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 0.79 | |||||||||
| Correction Factor at 40 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 0.91 | |||||||||
| Correction Factor at 45 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1 | |||||||||
| Correction Factor at 50 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1.09 | |||||||||
| Correction Factor at 55 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1.19 | |||||||||
| Correction Factor at 60 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1.27 | |||||||||
| Correction Factor at 80 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1.11 | |||||||||
| Correction Factor at 85 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1.08 | |||||||||
| Correction Factor at 90 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1.04 | |||||||||
| Correction Factor at 95 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1 | |||||||||
| Correction Factor at 100 Degree Fahrenheit (ºF) Ambient Temperature | N/A 0.93 | |||||||||
| Correction Factor at 105 Degree Fahrenheit (ºF) Ambient Temperature | N/A 0.91 | |||||||||
| Correction Factor at 113 Degree Fahrenheit (ºF) Ambient Temperature | N/A 0.83 | |||||||||
| Correction Factor at 0 Percent (%) Ethylene Glycol | N/A 1 | |||||||||
| Correction Factor at 10 Percent (%) Ethylene Glycol | N/A 0.99 | |||||||||
| Correction Factor at 20 Percent (%) Ethylene Glycol | N/A 0.98 | |||||||||
| Correction Factor at 30 Percent (%) Ethylene Glycol | N/A 0.97 | |||||||||
| Correction Factor at 40 Percent (%) Ethylene Glycol | N/A 0.96 | |||||||||
| Correction Factor at 45 Percent (%) Ethylene Glycol | N/A 0.95 | |||||||||
| Correction Factor at 50 Percent (%) Ethylene Glycol | N/A 0.94 | |||||||||
| Refrigerant Type | N/A R454A | |||||||||
| Benefits and Advantages |
N/A
Industrial water chillers offer protection to your valuable process equipment - such as spot welders, injection molding equipment, and various other industrial applications. A chiller provides solid protection of your investment twenty-four hours a day, seven day a week during the chiller's lifetime.
|
|||||||||
| Applications |
N/A
|
|||||||||
| Additional Information |
N/A
Industrial Process Cooling offers various-sized compact water and oil chillers, as well as large cooling systems to fit industrial applications. |
|||||||||
| Replaces | N/A IPC-0062 | N/A | N/A | N/A IPC-0092 | N/A | |||||
|
|
||||||||||





