Flex Flexible Industrial Process Chillers
Process Chillers
- Refrigerant R410A
- Scroll compressors
- High-efficiency shell & tube evaporators
- Free-cooling version available
Unit of Measure
| Items |
/Asset/a8654.jpg IPC-0062 6.2 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
/Asset/a8654.jpg IPC-0076 7.6 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
/Asset/a8654.jpg IPC-0092 9 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
/Asset/a8654.jpg IPC-0117 12 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
/Asset/a8654.jpg IPC-0141 14.1 Ton (t) Cooling Capacity Flex Flexible Industrial Process Chiller Web Price Quote
|
|||||
| Description |
N/A
|
|||||||||
| Brands | N/A IPC Industrial Process Cooling | |||||||||
| Cooling Capacity | N/A 6.2 ton74552 Btu/hr | N/A 7.6 ton90707 Btu/hr | N/A 9 ton110890 Btu/hr | N/A 12 ton140638 Btu/hr | N/A 14.1 ton168777 Btu/hr | |||||
| Fluid Connections | N/A 1-1/2 inMale Pipe Thread (MPT) | |||||||||
| Nominal Flow | N/A 16 gpm | N/A 20 gpm | N/A 25 gpm | N/A 30 gpm | N/A 35 gpm | |||||
| Nominal Head Pressure | N/A 60 psi | N/A 70 psi | N/A 70 psi | N/A 70 psi | N/A 70 psi | |||||
| Reservoir Capacity | N/A 32 gal | N/A 58 gal | N/A 58 gal | N/A 58 gal | N/A 58 gal | |||||
| Power Supply Voltage | N/A 460 V | |||||||||
| Power Supply Phase | N/A 3 | |||||||||
| Power Supply Frequency | N/A 60 Hz | |||||||||
| Full Load Current | N/A 20.2 A | N/A 25.0 A | N/A 26.9 A | N/A 31.8 A | N/A 38.2 A | |||||
| Length | N/A 31 in | |||||||||
| Width | N/A 23 in | |||||||||
| Height | N/A 18 in | |||||||||
| Installed Weight | N/A 995 lb | N/A 1,454 lb | N/A 1,459 lb | N/A 1,498 lb | N/A 1,498 lb | |||||
| Dry Weight | N/A 727 lb | N/A 970 lb | N/A 975 lb | N/A 1014 lb | N/A 1014 lb | |||||
| Fluid Out/In Temperature | N/A 45 ºF55 ºF | |||||||||
| Ambient Temperature | N/A 95 ºF | |||||||||
| Minimum Fluid Outlet Temperature | N/A 41 ºF | |||||||||
| Maximum Fluid Outlet Temperature | N/A 86 ºF | |||||||||
| Maximum Ambient Temperature | N/A 113 ºF | |||||||||
| Correction Factor at 30 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 0.68 | |||||||||
| Correction Factor at 35 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 0.79 | |||||||||
| Correction Factor at 40 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 0.91 | |||||||||
| Correction Factor at 45 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1 | |||||||||
| Correction Factor at 50 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1.09 | |||||||||
| Correction Factor at 55 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1.19 | |||||||||
| Correction Factor at 60 Degree Fahrenheit (ºF) Water Outlet Temperature | N/A 1.27 | |||||||||
| Correction Factor at 80 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1.11 | |||||||||
| Correction Factor at 85 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1.08 | |||||||||
| Correction Factor at 90 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1.04 | |||||||||
| Correction Factor at 95 Degree Fahrenheit (ºF) Ambient Temperature | N/A 1 | |||||||||
| Correction Factor at 100 Degree Fahrenheit (ºF) Ambient Temperature | N/A 0.93 | |||||||||
| Correction Factor at 105 Degree Fahrenheit (ºF) Ambient Temperature | N/A 0.91 | |||||||||
| Correction Factor at 113 Degree Fahrenheit (ºF) Ambient Temperature | N/A 0.83 | |||||||||
| Correction Factor at 0 Percent (%) Ethylene Glycol | N/A 1 | |||||||||
| Correction Factor at 10 Percent (%) Ethylene Glycol | N/A 0.99 | |||||||||
| Correction Factor at 20 Percent (%) Ethylene Glycol | N/A 0.98 | |||||||||
| Correction Factor at 30 Percent (%) Ethylene Glycol | N/A 0.97 | |||||||||
| Correction Factor at 40 Percent (%) Ethylene Glycol | N/A 0.96 | |||||||||
| Correction Factor at 45 Percent (%) Ethylene Glycol | N/A 0.95 | |||||||||
| Correction Factor at 50 Percent (%) Ethylene Glycol | N/A 0.94 | |||||||||
| Refrigerant Type | N/A R410A | |||||||||
| Benefits and Advantages |
N/A
Industrial water chillers offer protection to your valuable process equipment - such as spot welders, injection molding equipment, and various other industrial applications. A chiller provides solid protection of your investment twenty-four hours a day, seven day a week during the chiller's lifetime.
|
|||||||||
| Applications |
N/A
|
|||||||||
| Additional Information | N/A Industrial Process Cooling offers various-sized compact water and oil chillers, as well as large cooling systems to fit industrial applications. | |||||||||
|
|
||||||||||