Display shows 2 values at the same time:
- Present flow in m³/h, CFM
- Total consumption (counter reading) in CF
- Temperature measurement
Unit of Measure
Specifications
Parameters |
N/A m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases |
Units Adjustable Via Keys at Display |
N/A CFM ft/min g/s kg/h kg/min L/s lb/h lb/min m/s m³/h m³/min |
Sensor |
N/A Thermal Mass Flow Sensor |
Measured Medium |
N/A Air Gases |
Gas Types are Adjustable Over CS Service Software or CS Data Logger |
N/A Air Argon CO2 Nitrogen Oxygen |
Accuracy |
N/A ± 1.5% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) |
Accuracy on Request |
N/A ± 0.3% of Full Scale (F.S.) ± 1% of Measured Value (M.V.) |
Operating Temperature |
N/A -22 to 176 ºF |
Operating Temperature with Pressure Sensor |
N/A -25 to 349 ºF |
Operating Pressure |
N/A -1 to 232 psi |
Optional Pressure |
N/A Up to Nominal Pressure (PN) 40 |
Digital Output |
N/A (Modbus-RTU), Optional: Ethernet interface PoE) M-Bus RS 485 Interface |
Analog Output for Cubic Feet per Minute (CFM) |
N/A 4 to 20 mA |
Pulse Output |
N/A
1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display. Alternatively, the pulse output can be used as an alarm relay |
Direct Current Voltage (VDC) Supply |
N/A 18 to 36 V |
Power Supply |
N/A 5 W |
Burden |
N/A < 500 Ω |
Housing Material |
N/A Polycarbonate |
Protection Rating |
N/A Ingress Protection (IP 65) |
Measuring Section |
N/A Stainless Steel 1.4301 |
Mounting Position |
N/A Any |
Low-Speed Air Flow (164 Feet (ft)/Sec (s)) |
N/A 25 L/min0.9 cfm |
Standard Air Flow (304 Feet (ft)/Sec (s)) |
N/A 50 m³/h1.8 cfm |
Maximum Air Flow (607 Feet (ft)/Sec (s)) |
N/A 105 m³/h3.6 cfm |
High-Speed Air Flow (735 Feet (ft)/Sec (s)) |
N/A 130 m³/h4.5 cfm |
Note for Air Flow |
N/A Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi |
Low-Speed Argon (Ar) Flow (164 Feet (ft)/Sec (s)) |
N/A 45 L/min1.5 cfm |
Standard Argon (Ar) Flow (304 Feet (ft)/Sec (s)) |
N/A 85 m³/h3 cfm |
Maximum Argon (Ar) Flow (607 Feet (ft)/Sec (s)) |
N/A 170 m³/h6 cfm |
High-Speed Argon (Ar) Flow (735 Feet (ft)/Sec (s)) |
N/A 205 m³/h7.2 cfm |
Note for Argon (Ar) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Carbon Dioxide (CO2) Flow (164 Feet (ft)/Sec (s)) |
N/A 25 L/min0.9 cfm |
Standard Carbon Dioxide (CO2) Flow (304 Feet (ft)/Sec (s)) |
N/A 50 m³/h1.8 cfm |
Maximum Carbon Dioxide (CO2) Flow (607 Feet (ft)/Sec (s)) |
N/A 105 m³/h3.6 cfm |
High-Speed Carbon Dioxide (CO2) Flow (735 Feet (ft)/Sec (s)) |
N/A 130 m³/h4.5 cfm |
Note for Carbon Dioxide (CO2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrogen (N2) Flow (164 Feet (ft)/Sec (s)) |
N/A 25 L/min0.9 cfm |
Standard Nitrogen (N2) Flow (304 Feet (ft)/Sec (s)) |
N/A 50 m³/h1.5 cfm |
Maximum Nitrogen (N2) Flow (607 Feet (ft)/Sec (s)) |
N/A 100 m³/h3.3 cfm |
High-Speed Nitrogen (N2) Flow (735 Feet (ft)/Sec (s)) |
N/A 120 m³/h4.2 cfm |
Note for Nitrogen (N2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Oxygen (O2) Flow (164 Feet (ft)/Sec (s)) |
N/A 25 L/min0.9 cfm |
Standard Oxygen (O2) Flow (304 Feet (ft)/Sec (s)) |
N/A 50 m³/h1.8 cfm |
Maximum Oxygen (O2) Flow (607 Feet (ft)/Sec (s)) |
N/A 100 m³/h3.6 cfm |
High-Speed Oxygen (O2) Flow (735 Feet (ft)/Sec (s)) |
N/A 125 m³/h4.2 cfm |
Note for Oxygen (O2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrous Oxide (N2O) Flow (164 Feet (ft)/Sec (s)) |
N/A 25 L/min0.9 cfm |
Standard Nitrous Oxide (N2O) Flow (304 Feet (ft)/Sec (s)) |
N/A 50 m³/h1.8 cfm |
Maximum Nitrous Oxide (N2O) Flow (607 Feet (ft)/Sec (s)) |
N/A 105 m³/h3.6 cfm |
High-Speed Nitrous Oxide (N2O) Flow (735 Feet (ft)/Sec (s)) |
N/A 125 m³/h4.5 cfm |
Note for Nitrous Oxide (N2O) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Natural Gas (NG) Flow (164 Feet (ft)/Sec (s)) |
N/A 15 L/min0.6 cfm |
Standard Natural Gas (NG) Flow (304 Feet (ft)/Sec (s)) |
N/A 30 m³/h0.9 cfm |
Maximum Natural Gas (NG) Flow (607 Feet (ft)/Sec (s)) |
N/A 60 m³/h2.1 cfm |
High-Speed Natural Gas (NG) Flow (735 Feet (ft)/Sec (s)) |
N/A 75 m³/h2.7 cfm |
Note for Natural Gas (NG) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Connection Thread |
N/A R 1/4 in. |
Thread Outer Pipe Diameter |
N/A 13.7 mm0.54 in |
Thread Inner Pipe Diameter |
N/A 8.9 mm0.35 in |
Dimension L (Thread) |
N/A 7.6 Inch194 mm |
Dimension L1 (Thread) |
N/A 5.3 in137 mm |
Dimension H (Thread) |
N/A 6.8 in174.7 mm |
Dimension H1 (Thread) |
N/A 6.5 in165.7 mm |
Dimension A (Thread) |
N/A 0.5 in15 mm |
Connection to different Bus systems Options |
N/A
There are different options available for connection to modern Bus systems:
|
With a Key Stroke |
N/A
|
Options |
N/A
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow. A meter reading is available for each flow direction. |
Application-Technological Features |
N/A
|
Additional Information |
N/A
Modbus-RTU output 4 to 20 mA output for present flow Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally) NEW: Integrated pressure sensor (optional) Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40) High measuring accuracy due to defined measuring section (inlet and outlet section) Display head rotatable by 180º e.g. in case of reverse flow direction The sensor can be removed and cleaned. |