Display shows 2 values at the same time:
  • Present flow in m³/h, CFM
  • Total consumption (counter reading) in CF
  • Temperature measurement
Readout values in the display can be rotated by 180º, e.g. for overhead installation.
Unit of Measure

Specifications

Parameters

N/A m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases

Units Adjustable Via Keys at Display

N/A CFM ft/min g/s kg/h kg/min L/s lb/h lb/min m/s m³/h m³/min

Sensor

N/A Thermal Mass Flow Sensor

Measured Medium

N/A Air Gases

Gas Types are Adjustable Over CS Service Software or CS Data Logger

N/A Air Argon CO2 Nitrogen Oxygen

Accuracy

N/A ± 1.5% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.)

Accuracy on Request

N/A ± 0.3% of Full Scale (F.S.) ± 1% of Measured Value (M.V.)

Operating Temperature

N/A -22 to 176 ºF

Operating Temperature with Pressure Sensor

N/A -25 to 349 ºF

Operating Pressure

N/A -1 to 232 psi

Optional Pressure

N/A Up to Nominal Pressure (PN) 40

Digital Output

N/A (Modbus-RTU), Optional: Ethernet interface PoE) M-Bus RS 485 Interface

Analog Output for Cubic Feet per Minute (CFM)

N/A 4 to 20 mA

Pulse Output

N/A 1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display.
Alternatively, the pulse output can be used as an alarm relay

Direct Current Voltage (VDC) Supply

N/A 18 to 36 V

Power Supply

N/A 5 W

Burden

N/A < 500 Ω

Housing Material

N/A Polycarbonate

Protection Rating

N/A Ingress Protection (IP 65)

Measuring Section

N/A Stainless Steel 1.4301 1-1/2 in

Mounting Position

N/A Any

Low-Speed Air Flow (164 Feet (ft)/Sec (s))

N/A 195 L/min115 cfm

Standard Air Flow (304 Feet (ft)/Sec (s))

N/A 365 m³/h215 cfm

Maximum Air Flow (607 Feet (ft)/Sec (s))

N/A 730 m³/h430 cfm

High-Speed Air Flow (735 Feet (ft)/Sec (s))

N/A 885 m³/h520 cfm

Note for Air Flow

N/A Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi

Low-Speed Argon (Ar) Flow (164 Feet (ft)/Sec (s))

N/A 305 L/min180 cfm

Standard Argon (Ar) Flow (304 Feet (ft)/Sec (s))

N/A 570 m³/h335 cfm

Maximum Argon (Ar) Flow (607 Feet (ft)/Sec (s))

N/A 1140 m³/h670 cfm

High-Speed Argon (Ar) Flow (735 Feet (ft)/Sec (s))

N/A 1385 m³/h815 cfm

Note for Argon (Ar) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Carbon Dioxide (CO2) Flow (164 Feet (ft)/Sec (s))

N/A 195 L/min115 cfm

Standard Carbon Dioxide (CO2) Flow (304 Feet (ft)/Sec (s))

N/A 360 m³/h210 cfm

Maximum Carbon Dioxide (CO2) Flow (607 Feet (ft)/Sec (s))

N/A 720 m³/h425 cfm

High-Speed Carbon Dioxide (CO2) Flow (735 Feet (ft)/Sec (s))

N/A 875 m³/h515 cfm

Note for Carbon Dioxide (CO2) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Nitrogen (N2) Flow (164 Feet (ft)/Sec (s))

N/A 295 L/min175 cfm

Standard Nitrogen (N2) Flow (304 Feet (ft)/Sec (s))

N/A 335 m³/h195 cfm

Maximum Nitrogen (N2) Flow (607 Feet (ft)/Sec (s))

N/A 670 m³/h395 cfm

High-Speed Nitrogen (N2) Flow (735 Feet (ft)/Sec (s))

N/A 815 m³/h475 cfm

Note for Nitrogen (N2) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Oxygen (O2) Flow (164 Feet (ft)/Sec (s))

N/A 185 L/min110 cfm

Standard Oxygen (O2) Flow (304 Feet (ft)/Sec (s))

N/A 345 m³/h205 cfm

Maximum Oxygen (O2) Flow (607 Feet (ft)/Sec (s))

N/A 695 m³/h410 cfm

High-Speed Oxygen (O2) Flow (735 Feet (ft)/Sec (s))

N/A 845 m³/h495 cfm

Note for Oxygen (O2) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Nitrous Oxide (N2O) Flow (164 Feet (ft)/Sec (s))

N/A 190 L/min110 cfm

Standard Nitrous Oxide (N2O) Flow (304 Feet (ft)/Sec (s))

N/A 355 m³/h210 cfm

Maximum Nitrous Oxide (N2O) Flow (607 Feet (ft)/Sec (s))

N/A 715 m³/h420 cfm

High-Speed Nitrous Oxide (N2O) Flow (735 Feet (ft)/Sec (s))

N/A 865 m³/h510 cfm

Note for Nitrous Oxide (N2O) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Low-Speed Natural Gas (NG) Flow (164 Feet (ft)/Sec (s))

N/A 115 L/min65 cfm

Standard Natural Gas (NG) Flow (304 Feet (ft)/Sec (s))

N/A 215 m³/h125 cfm

Maximum Natural Gas (NG) Flow (607 Feet (ft)/Sec (s))

N/A 430 m³/h250 cfm

High-Speed Natural Gas (NG) Flow (735 Feet (ft)/Sec (s))

N/A 520 m³/h305 cfm

Note for Natural Gas (NG) Flow

N/A Setting to DIN 1343: 32 ºF, 14.7 psi

Flange Outer Pipe Diameter

N/A 48.3 mm1.9 in

Flange Inner Pipe Diameter

N/A 41.9 mm1.65 in

Dimension L (Flange)

N/A 18.7 in

Note for Dimension L (Flange)

N/A Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site.

Dimension L1 (Flange)

N/A 10.83 in

Dimension H (Flange)

N/A 9.4 in

Dimension H1 (Flange)

N/A 6.5 in

Diameter D (Flange)

N/A 150 mm

Diameter K (Flange)

N/A 110 mm

n x Diameter L (Flange)

N/A 4 x 18

Connection Thread

N/A R 1-1/2 in.

Thread Outer Pipe Diameter

N/A 48.3 mm1.90 in

Thread Inner Pipe Diameter

N/A 41.9 mm1.65 in

Dimension L (Thread)

N/A 18.7 Inch475 mm

Note for Dimension L (Thread)

N/A Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site!

Dimension L1 (Thread)

N/A 10.8 in275 mm

Dimension H (Thread)

N/A 7.3 in186.9 mm

Dimension H1 (Thread)

N/A 6.5 in165.7 mm

Dimension A (Thread)

N/A 0.9 in25 mm

Connection to different Bus systems Options

N/A There are different options available for connection to modern Bus systems:
  • Ethernet interface (Modbus-TCP) / PoE
  • M-BUS
  • Modbus-RTU

With a Key Stroke

N/A
  • Reset counter reading
  • Select units
  • Zero-point adjustment, leak flow volume suppression

Options

N/A Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow.
A meter reading is available for each flow direction.

Application-Technological Features

N/A
  • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy management
  • Systems, building management systems, PLC
  • Easy and affordable installation
  • Units freely selectable via keys on the display CF, lbs, CFM
  • Compressed air counter up to 1,999,999,999 m³ can be reset to Inch (in)zero Inch (in) via keypad
  • Analog output 4 to 20 mA, pulse output (electrically isolated)
  • High measuring accuracy even in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min
  • values ºF, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus

Additional Information

N/A Modbus-RTU output
4 to 20 mA output for present flow

Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally)

NEW: Integrated pressure sensor (optional)

Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary

Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40)

High measuring accuracy due to defined measuring section (inlet and outlet section)

Display head rotatable by 180º e.g. in case of reverse flow direction

The sensor can be removed and cleaned.