Display shows 2 values at the same time:
- Present flow in m³/h, CFM
- Total consumption (counter reading) in CF
- Temperature measurement
Unit of Measure
Specifications
Parameters |
N/A m³/h, CFM (1000 mbar, 20 ºC) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0ºC) In Case of Gases |
Units Adjustable Via Keys at Display |
N/A CFM ft/min g/s kg/h kg/min L/s lb/h lb/min m/s m³/h m³/min |
Sensor |
N/A Thermal Mass Flow Sensor |
Measured Medium |
N/A Air Gases |
Gas Types are Adjustable Over CS Service Software or CS Data Logger |
N/A Air Argon CO2 Nitrogen Oxygen |
Accuracy |
N/A ± 1.5% of Measured Value (M.V.) ± 0.3% of Full Scale (F.S.) |
Accuracy on Request |
N/A ± 0.3% of Full Scale (F.S.) ± 1% of Measured Value (M.V.) |
Operating Temperature |
N/A -22 to 176 ºF |
Operating Temperature with Pressure Sensor |
N/A -25 to 349 ºF |
Operating Pressure |
N/A -1 to 232 psi |
Optional Pressure |
N/A Up to Nominal Pressure (PN) 40 |
Digital Output |
N/A (Modbus-RTU), Optional: Ethernet interface PoE) M-Bus RS 485 Interface |
Analog Output for Cubic Feet per Minute (CFM) |
N/A 4 to 20 mA |
Pulse Output |
N/A
1 pulse per CF or per litre electrically isolated. Pulse weight can be set on the display. Alternatively, the pulse output can be used as an alarm relay |
Direct Current Voltage (VDC) Supply |
N/A 18 to 36 V |
Power Supply |
N/A 5 W |
Burden |
N/A < 500 Ω |
Housing Material |
N/A Polycarbonate |
Protection Rating |
N/A Ingress Protection (IP 65) |
Measuring Section |
N/A Stainless Steel 1.4301 2 in |
Mounting Position |
N/A Any |
Low-Speed Air Flow (164 Feet (ft)/Sec (s)) |
N/A 320 L/min190 cfm |
Standard Air Flow (304 Feet (ft)/Sec (s)) |
N/A 600 m³/h350 cfm |
Maximum Air Flow (607 Feet (ft)/Sec (s)) |
N/A 1195 m³/h700 cfm |
High-Speed Air Flow (735 Feet (ft)/Sec (s)) |
N/A 1450 m³/h850 cfm |
Note for Air Flow |
N/A Reference conditions DIN 1945 / ISO 1217: 68 ºF, 14 psi |
Low-Speed Argon (Ar) Flow (164 Feet (ft)/Sec (s)) |
N/A 505 L/min295 cfm |
Standard Argon (Ar) Flow (304 Feet (ft)/Sec (s)) |
N/A 935 m³/h550 cfm |
Maximum Argon (Ar) Flow (607 Feet (ft)/Sec (s)) |
N/A 1870 m³/h1100 cfm |
High-Speed Argon (Ar) Flow (735 Feet (ft)/Sec (s)) |
N/A 2265 m³/h1330 cfm |
Note for Argon (Ar) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Carbon Dioxide (CO2) Flow (164 Feet (ft)/Sec (s)) |
N/A 320 L/min185 cfm |
Standard Carbon Dioxide (CO2) Flow (304 Feet (ft)/Sec (s)) |
N/A 590 m³/h345 cfm |
Maximum Carbon Dioxide (CO2) Flow (607 Feet (ft)/Sec (s)) |
N/A 1185 m³/h695 cfm |
High-Speed Carbon Dioxide (CO2) Flow (735 Feet (ft)/Sec (s)) |
N/A 1430 m³/h840 cfm |
Note for Carbon Dioxide (CO2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrogen (N2) Flow (164 Feet (ft)/Sec (s)) |
N/A 505 L/min300 cfm |
Standard Nitrogen (N2) Flow (304 Feet (ft)/Sec (s)) |
N/A 550 m³/h320 cfm |
Maximum Nitrogen (N2) Flow (607 Feet (ft)/Sec (s)) |
N/A 1100 m³/h645 cfm |
High-Speed Nitrogen (N2) Flow (735 Feet (ft)/Sec (s)) |
N/A 1330 m³/h780 cfm |
Note for Nitrogen (N2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Oxygen (O2) Flow (164 Feet (ft)/Sec (s)) |
N/A 305 L/min180 cfm |
Standard Oxygen (O2) Flow (304 Feet (ft)/Sec (s)) |
N/A 570 m³/h335 cfm |
Maximum Oxygen (O2) Flow (607 Feet (ft)/Sec (s)) |
N/A 1140 m³/h670 cfm |
High-Speed Oxygen (O2) Flow (735 Feet (ft)/Sec (s)) |
N/A 1380 m³/h810 cfm |
Note for Oxygen (O2) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Nitrous Oxide (N2O) Flow (164 Feet (ft)/Sec (s)) |
N/A 315 L/min185 cfm |
Standard Nitrous Oxide (N2O) Flow (304 Feet (ft)/Sec (s)) |
N/A 585 m³/h345 cfm |
Maximum Nitrous Oxide (N2O) Flow (607 Feet (ft)/Sec (s)) |
N/A 1170 m³/h690 cfm |
High-Speed Nitrous Oxide (N2O) Flow (735 Feet (ft)/Sec (s)) |
N/A 1420 m³/h835 cfm |
Note for Nitrous Oxide (N2O) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Low-Speed Natural Gas (NG) Flow (164 Feet (ft)/Sec (s)) |
N/A 190 L/min110 cfm |
Standard Natural Gas (NG) Flow (304 Feet (ft)/Sec (s)) |
N/A 355 m³/h205 cfm |
Maximum Natural Gas (NG) Flow (607 Feet (ft)/Sec (s)) |
N/A 705 m³/h415 cfm |
High-Speed Natural Gas (NG) Flow (735 Feet (ft)/Sec (s)) |
N/A 855 m³/h500 cfm |
Note for Natural Gas (NG) Flow |
N/A Setting to DIN 1343: 32 ºF, 14.7 psi |
Flange Outer Pipe Diameter |
N/A 60.3 mm2.37 in |
Flange Inner Pipe Diameter |
N/A 53.1 mm2.09 in |
Dimension L (Flange) |
N/A 18.7 in |
Note for Dimension L (Flange) |
N/A Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site. |
Dimension L1 (Flange) |
N/A 10.83 in |
Dimension H (Flange) |
N/A 9.7 in |
Dimension H1 (Flange) |
N/A 6.5 in |
Diameter D (Flange) |
N/A 165 mm |
Diameter K (Flange) |
N/A 125 mm |
n x Diameter L (Flange) |
N/A 4 x 18 |
Connection Thread |
N/A R 2 in. |
Thread Outer Pipe Diameter |
N/A 60.3 mm2.37 in |
Thread Inner Pipe Diameter |
N/A 53.1 mm2.09 in |
Dimension L (Thread) |
N/A 18.7 Inch475 mm |
Note for Dimension L (Thread) |
N/A Attention: Shortened inlet section. Please observe the recommended minimum inlet section (length = 15 x inner diameter) on site! |
Dimension L1 (Thread) |
N/A 10.8 in275 mm |
Dimension H (Thread) |
N/A 7.7 in195.9 mm |
Dimension H1 (Thread) |
N/A 6.5 in165.7 mm |
Dimension A (Thread) |
N/A 1.1 in30 mm |
Connection to different Bus systems Options |
N/A
There are different options available for connection to modern Bus systems:
|
With a Key Stroke |
N/A
|
Options |
N/A
Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow. A meter reading is available for each flow direction. |
Application-Technological Features |
N/A
|
Additional Information |
N/A
Modbus-RTU output 4 to 20 mA output for present flow Pulse output for total flow (counter reading), galvanically isolated or M-Bus (optionally) NEW: Integrated pressure sensor (optional) Measuring unit can be unscrewed: Removal of the entire measuring section not necessary, no by-pass necessary Easy installation into the existing pipeline due to integrated measuring section and weld neck flange (according to EN 1092-1 PN 40) High measuring accuracy due to defined measuring section (inlet and outlet section) Display head rotatable by 180º e.g. in case of reverse flow direction The sensor can be removed and cleaned. |