Specifications
Model |
N/A HRC 1002 |
Phase |
N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Air Flow at 50 Hertz (Hz) Frequency |
N/A 188 ft³/min320 m³/h |
Air Flow at 60 Hertz (Hz) Frequency |
N/A 227 ft³/min385 m³/h |
Rated Vacuum at 50 Hertz (Hz) Frequency |
N/A 177 in. H2O440 mbar |
Rated Vacuum at 60 Hertz (Hz) Frequency |
N/A 185 in. H2O460 mbar |
Rated Pressure at 50 Hertz (Hz) Frequency |
N/A 229 in. H2O570 mbar |
Rated Pressure at 60 Hertz (Hz) Frequency |
N/A 269 in. H2O660 mbar |
Motor Power at 50 Hertz (Hz) Frequency |
N/A 10.1 hp7.5 kW |
Motor Power at 60 Hertz (Hz) Frequency |
N/A 11.5 hp8.6 kW |
Voltage (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 190 V |
Voltage (Δ) at 50 Hertz (Hz) Frequency |
N/A 380 V |
Voltage (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 230 V |
Voltage (Δ) at 60 Hertz (Hz) Frequency |
N/A 460 V |
Current (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 33.4 A |
Current (Δ) at 50 Hertz (Hz) Frequency |
N/A 16.7 A |
Current (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 30.0 A |
Current (Δ) at 60 Hertz (Hz) Frequency |
N/A 17.3 A |
Sound Level at 50 Hertz (Hz) Frequency |
N/A 73 dB |
Sound Level at 60 Hertz (Hz) Frequency |
N/A 76 dB |
Weight |
N/A 163 lb74 kg |
Dimensions
Dimension A |
N/A 24.88 in632 mm |
Dimension B |
N/A 19.63 in499 mm |
Dimension C |
N/A 24.00 in610 mm |
Dimension D |
N/A 16.19 in412 mm |
Dimension E |
N/A 12.00 in305 mm |
Dimension F |
N/A 4.50 in115 mm |
Dimension G |
N/A 9.38 in239 mm |
Dimension H |
N/A 6.69 in169 mm |
Dimension J |
N/A 2.56 in65 mm |
Certification
Certification |
N/A Canadian Underwriters Laboratories (cUL) European Conformity (CE) International Efficiency Class 3 - CC339B (IE3) Underwriters Laboratories Recognized Component for Canada (c) and United States (us)) - E493872 |
Available Options
|
N/A All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. |
Note
|
N/A The performance curves are based on air at a temperature of 59 ºF and an atmospheric pressure of 29.91 inch Hg with a tolerance of ±10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 ºF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are ±10% for fixed voltage motors and ±5% for voltage range motors. Single phase machines are designed with a ±5% tolerance. The frequency tolerance is ±2% maximum. |