Specifications
Model |
N/A HRC 1060 |
Phase |
N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Air Flow at 50 Hertz (Hz) Frequency |
N/A 412 ft³/min700 m³/h |
Air Flow at 60 Hertz (Hz) Frequency |
N/A 494 ft³/min840 m³/h |
Rated Vacuum at 50 Hertz (Hz) Frequency |
N/A 108 in. H2O270 mbar |
Rated Vacuum at 60 Hertz (Hz) Frequency |
N/A 108 in. H2O270 mbar |
Rated Pressure at 50 Hertz (Hz) Frequency |
N/A 104 in. H2O260 mbar |
Rated Pressure at 60 Hertz (Hz) Frequency |
N/A 104 in. H2O260 mbar |
Motor Power at 50 Hertz (Hz) Frequency |
N/A 10.0 hp7.5 kW |
Motor Power at 60 Hertz (Hz) Frequency |
N/A 11.5 hp8.6 kW |
Voltage (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 190 V |
Voltage (Δ) at 50 Hertz (Hz) Frequency |
N/A 380 V |
Voltage (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 230 V |
Voltage (Δ) at 60 Hertz (Hz) Frequency |
N/A 460 V |
Current (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 33.4 A |
Current (Δ) at 50 Hertz (Hz) Frequency |
N/A 16.7 A |
Current (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 30.0 A |
Current (Δ) at 60 Hertz (Hz) Frequency |
N/A 17.3 A |
Sound Level at 50 Hertz (Hz) Frequency |
N/A 70 dB |
Sound Level at 60 Hertz (Hz) Frequency |
N/A 74 dB |
Weight |
N/A 153 lb69 kg |
Dimensions
Dimension A |
N/A 17.76 in451 mm |
Dimension B |
N/A 19.80 in503 mm |
Dimension D |
N/A M10 |
Dimension E |
N/A 19.37 in492 mm |
Dimension F |
N/A 6.46 in164 mm |
Dimension G |
N/A 8.90 in226 mm |
Dimension J |
N/A 7.76 in197 mm |
Dimension K |
N/A 9.41 in239 mm |
Dimension M |
N/A 2.50 in |
Dimension N |
N/A 3.70 in94 mm |
Dimension O |
N/A 0.24 in6 mm |
Dimension P |
N/A 2.52 in64 mm |
Dimension Q |
N/A 8.54 in217 mm |
Dimension R |
N/A 15.51 in394 mm |
Dimension S |
N/A 14.02 in356 mm |
Dimension t |
N/A 5.47 in139 mm |
Dimension u |
N/A 6.69 in170 mm |
Dimension V |
N/A 17.64 in448 mm |
Dimension W |
N/A 0.59 in15 mm |
Certification
Certification |
N/A Canadian Underwriters Laboratories (cUL) European Conformity (CE) International Efficiency Class 3 - CC339B (IE3) Underwriters Laboratories Recognized Component for Canada (c) and United States (us)) - E493872 |
Available Options
|
N/A All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. |
Note
|
N/A The performance curves are based on air at a temperature of 59 ºF and an atmospheric pressure of 29.91 inch Hg with a tolerance of ±10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 ºF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are ±10% for fixed voltage motors and ±5% for voltage range motors. Single phase machines are designed with a ±5% tolerance. The frequency tolerance is ±2% maximum. |